奥氏体不锈钢管热挤压过程挤压针冷却工艺的优化

王伯文1,刘升2,康喜唐1,段政均1,拓雷锋1,李强1   

  1. 1. 山西太钢不锈钢钢管有限公司,太原 030008;
    2. 武汉科技大学钢铁冶金及资源利用省部共建教育部重点实验室,武汉 430081;
  • 收稿日期:2016-04-20 出版日期:2016-10-01 发布日期:2022-07-29
  • 作者简介:王伯文(1984-),男,硕士(2009年武汉科技大学),工程师,2005年武汉科技大学(本科)毕业,不锈钢及镣铁合金管材、型材的产品开发和控制。

Optimization of Cooling Process of Extruding Needle in Hot Extrusion of Austenite Stainless Steel Tube

Wang Bowen1 , Liu Sheng2 , Kang Xitang1 , Duan Zhenjun1 , Tuo Leifeng1 , Li Qiang1   

  1. 1. Shanxi Taigang Stainless Steel Tubes & Pipes Co Ltd, Taiyuan 030008 ;
    2. Key Lab for Ferrous Metallurgy and Resources Utilization of Ministry of Education, Wuhan University of Science and Technology, Wuhan 430081;
  • Received:2016-04-20 Published:2016-10-01 Online:2022-07-29

摘要: 通过有限元软件Ansys对TP304奥氏体不锈钢管热挤压过程工模具的温度和传热进行模拟,得出X38CrMoV5-3模具钢挤压针在热挤压过程温度及热流量的分布,并计算得出生产不同规格钢管时挤压针的规格和所需水体积。Φ57.0 mm×6.3 mm~Φ139.7 mm×20.0 mm TP304不锈钢管的生产应用,结果表明,冷却工艺改进后,外径<100 mm挤压针的使用寿命由50~100次/支增加到100~150次/支,外径≥100 mm挤压针的使用寿命由100~200次/支提高到150~250次/支,显著降低成本和提高生产率。

关键词: 奥氏体不锈钢管, 热挤压, X38CrMoV5-3模具钢, 挤压针, 冷却工艺

Abstract: By finite element software Ansys the simulation on temperature and heat transfer of tool and die in hot extrusion process of TP304 austenite stainless steel tube to get the distribution of temperature and heat flux of die steel X38CrMoV5-3 extruding needle in hot extrusion process and the specification parameters and needed water volume for extruding different tube sizes are obtained by calculation. The application of production of φ57.0 mm X 6.3 mm~φ139.7 mm x 20.0 mm TP304 austenite stainless steel tubes show that with improvement o£ cooling process the service life of extruding needle with outside diameter <100 mm increases from 50~100 times/per piece to 100~150 times/per piece, and that with outside diameter ≥100 mm increases from 100~200 times/per piece to 150~200 times/per piece, the production cost decreases and the production rate increases obviously.