Based on the analysis of the key influencing factors of H2S corrosion resistant steel plate ( wass fraction/% :0.16C
0.32Si
1.25Mn
0.018Al
0.0007S
0.007P) in failure process
the mechanism of H
2
S corrosion failure and the method of improving the corrosion resistance of H
2
S are illustrated by comparing the influence of inclusion and banded structure on H
2
S corrosion performance. The results show that MnS inclusion and continuous banded structure are the key factors that lead to the corrosion cracking of H
2
S
and the HIC corrosion performance can be obviously improved as the banded structure is changed by continuous-intermittent twice 880 ℃ as 60 min normalized treatment and the Length crack sensitivity is 0.