孙增淼, 邸永田, 姜方, et al. Analysis on Surface Cracks of Martensitic Steel 40Crl0Si2Mo Wire and Process Improvement[J]. Special Steel, 2020, 41(5): 22-24.DOI:
the surface cracks are found on the polished rod surface of steel 40Crl0Si2Mo 6. 5 mm wire rod. Through the simulation test of quenching and tempering of steel 40Crl0Si2Mo
it is obtained that the reason for the surface crack of steel 40Crl0Si2Mo wire rod is the short cooling time after hot rolling
the cooling speed is fast
and there is a large residual stress on the surface of the hot rolled wire rod leading to form the surface crack. The production process of steel 40Crl0Si2Mo is optimized and improved
including prolonging Stelmo roller slow cooling time
adjusting the finishing rolling temperature and lay-off temperature from 900 ~ 950 °C and 850 〜900 °C to 800 〜850 °C
and within 24 hours after rolling to anneal the wire
the surface crack of steel 40Crl0Si2Mo product has been avoided.