ISSN:1003-8620

CN:42-1243/TF

主管:中信泰富特钢集团股份有限公司

主办:大冶特殊钢有限公司

特殊钢 ›› 2013, Vol. 34 ›› Issue (2): 7-10.

• 试验研究 • 上一篇    下一篇

45钢中厚板矫直过程温度场有限元模拟及残余应力分析

刘炼,任勇,程晓茹,李春光,尹皓,詹三林   

  1. 武汉科技大学材料与冶金学院,武汉 430081
  • 收稿日期:2012-09-26 出版日期:2013-04-01 发布日期:2022-09-30
  • 通讯作者: 任 勇
  • 作者简介:刘炼(1987-),男,硕士研究生,塑性成形工艺优化和计算机模拟。

Finite Element Simulation on Temperature Field of 0.45C Steel Medium and Heavy Plate during Straightening Process and Residual Stress Analysis

Liu Lian , Ren Yong , Cheng Xiaoru , Li Chunguang , Yin Hao , Zhan Sanlin   

  1. College of Science and Metallurgical Engineering, Wuhan University of Science and Technology, Wuhan 430081
  • Received:2012-09-26 Published:2013-04-01 Online:2022-09-30
  • Contact: Ren Yong

摘要: 运用有限元软件ABAQUS建立了中厚板矫直过程三维热力耦合温度模型,通过对45钢中厚板的模拟仿真计算和分析,得出初始温度520℃的20 mm板和初始温度605℃的55 mm板矫直过程纵向、横向和厚度方向的温度分布和变化,并分析了20 mm板初始温度420~620℃、55 mm板初始温度505~705℃原始曲率0.07~0.20时钢板矫直初始温度和原始曲率对矫直后钢板残余应力的影响。计算结果表明,矫直前温度越低,原始曲率越大矫直后残余应力越大;520℃20 mm板矫直后温度为505.4℃,矫直力为2 161.69 kN,605℃55 mm板矫直后温度589.3℃,矫直力4 565.49 kN,其实测值分别为507℃,2 272.93 kN和591℃,4 397.94 kN。说明计算值误差较小。

关键词: 45钢, 中厚板, 矫直过程, 有限元模拟, 温度场, 残余应力

Abstract: The three dimensional thermo-mechanical coupling model of temperature field for medium and heavy plate during straightening process is established by finite element software ABAQUS. The temperature distribution and change of temperature of 20 mm plate with initial temperature 520 ℃ and 55 mm plate with initial temperature 605 Y along plate longitudinal ,transverse and thickness direction during straightening process are obtained by simulated calculation and analysis on 0.45 C steel medium and heavy plate, and the effect of plate straightening initial temperature (20 mm plate 420-620 ℃ and 55 mm plate 505-705 ℃) and initial curvature (0.07-0.20) on residual stress in straightened plate is analyzed. Calculated results show that the lower temperature before straightening, the larger residual stress after straightening ; for 520 ℃ 20 mm plate, the temperature of plate after straightening is 505.4 ℃ and the straightening force is 2 161.69 kN, for 605 ℃ 55 mm plate the temperature of plate after straightening is 589.3 °C and the straightening force is 4565.49 kN, their measured values are respectively 507 ℃, 2272.93 kN and 591 Y , 4397.94 kN. It indicated that the error of calculated value is minor.

Key words: 0.45 C Steel, Medium and Heavy Plate, Straightening Process, Finite Element Simulation, Temperature Field, Residual Stress