钎焊式空冷系统用嵌入式冷轧铝-钢复合带材的开发

李 龙,张小军, 曾祥勇, 陈 鑫, 高 闯, 周德敬   

  1. 银邦金属复合材料股份有限公司江苏省金属层状复合材料重点实验室,无锡214145
  • 收稿日期:2014-08-28 出版日期:2015-02-01 发布日期:2022-08-29
  • 作者简介:李 龙(1977-),男,博士(东北大学),高级工程师,2004年 内蒙古科技大学(本科)毕业,金属层状复合材料技术开发。
  • 基金资助:
    国家高技术研究发展计划(863) (2013AA031301);
    国家国际科技合作专项项目(2013DFB50170);
    江苏 省科技成果转化专项资金项目(BA2011038);
    江苏重点实验室资助项目(BM2014006)。

Development of Embedded Aluminum-Steel Cladding Strip for Brazed Air Cooling System by Cold Rolling Bonding

Li Long, Zhang Xiaqjun, Zeng Xiangyong, Chen Xin, Gao Chuang , Zhou Dejing   

  1. Jiangsu Key Laboratory for Clad Materials, Yinbang Clad Material Co Ltd, Wuxi 214145
  • Received:2014-08-28 Published:2015-02-01 Online:2022-08-29

摘要: 通过"表面处理+冷轧复合+退火处理"三步法,即先采用钢丝刷对4 mm 08Al钢(/%:0.01C,0.018Al)和0.23 mm 4A60铝带表面进行处理,然后在前张力30 kN下利用高精度Φ420 mm四辊轧机对铝-钢进行60%的单道次冷轧复合,并于罩式退火炉进行520℃24 h的退火处理,开发出了极薄复层(80~90μm)冷轧4A60铝/08Al钢1.7 mm复合带材。复合带材中08Al钢的组织为平均晶粒尺寸15μm的等轴铁素体,抗拉强度≥320MPa,伸长率≥28%,弯曲性能也符合指标要求。复合带材在(600±10) ℃ 钎焊后铝钢界面未发现金属间化合物,铝钢界面未发现分层现象。

关键词: 铝-钢复合带材, 冷轧复合, 嵌入式, 力学性能, 结合性能

Abstract: With three-step method “surface process + cold rolling bonding + annealing treatment", i. e. first, treating the surface of 4mm 08 Al steel strip (/% : 0. 01G, 0. 018A1) and 0.23 mm 4A60 aluminium strip by brushing, then single pass-rolled by 60% reduction for the aluminium-steel strip using high precision Φ420 mm four high rolling mill with 30 kN forward tension to get large deformation cladding, and annealing treatment at 520 ℃ for 24 h in a bell type annealing furnace, the cold-rolled 1. 7 mm 4A60 aluminium-08Al steel cladding strip with 80 〜90 μm extra-thin cladding layer is developed. The microstructure of 08Al steel in cladding strip is equiaxed ferrite with average grain size 15 μm, its tensile strength ≥320MPa and elongation ≥28%, and the bending properties of cladding strip also meet the requirement of standard. The intermetallic compound is not found in aluminum-steel interface region of cladding strip brazed at (600 ± 10) ℃, and the delamination phenomenon is not observed at interface of aluminium and steel.