Process Practice of Deep Dephosphorization Technology of 200t Top and Bottom Combined Blowing Converter with Semi-Steel
|更新时间:2026-01-21
|
Process Practice of Deep Dephosphorization Technology of 200t Top and Bottom Combined Blowing Converter with Semi-Steel
Special SteelVol. 38, Issue 6, Pages: 40-44(2017)
作者机构:
1. 攀钢集团研究院有限公司,钒钛资源综合利用国家重点实验室,攀枝花,617000
2. 攀钢集团西昌钢钒有限公司,西昌,615000
作者简介:
基金信息:
DOI:
CLC:
Received:05 June 2017,
Online First:12 July 2022,
Published:12 July 2017
稿件说明:
移动端阅览
陈均, 江南红, 龚洪君, et al. Process Practice of Deep Dephosphorization Technology of 200t Top and Bottom Combined Blowing Converter with Semi-Steel[J]. Special Steel, 2017, 38(6): 40-44.
DOI:
陈均, 江南红, 龚洪君, et al. Process Practice of Deep Dephosphorization Technology of 200t Top and Bottom Combined Blowing Converter with Semi-Steel[J]. Special Steel, 2017, 38(6): 40-44.DOI:
Process Practice of Deep Dephosphorization Technology of 200t Top and Bottom Combined Blowing Converter with Semi-Steel
According to the issue of high phosphorus content in liquid with great fluctuation at end-point of converter
the difficult points for control of deep dephosphorization of liquid and the influence factors on dephosphorization are analyzed
and to use the deep dephosphorization process scheme of “double slagging catch carbon method” is proposed. With the dephosphorization measures including optimizing slagging
oxygen supplying
bottom gas blowing and lance level and end point control
the results of 9 heats of steel 34CrMo4 steelmaking shows that the dephosphorization rate of liquid is up to 84.6%
the end slag-steel phosphor partition ratio Lp is up to 90.1 to realize the stable control on converter liquid end [P]≤0.006%
and with using the technology measures of skateboard and reformed top slag to reduce rephosphorization
the ability of batch steelmaking low phosphorus steel with phosphorus content less than 0. 010% is qualified.