Analysis on Strip Fracture of High Strength IF Steel Containing Phosphorus During Straightening in Pickling & Rolling and Process Improvement
|更新时间:2026-01-21
|
Analysis on Strip Fracture of High Strength IF Steel Containing Phosphorus During Straightening in Pickling & Rolling and Process Improvement
Special SteelVol. 40, Issue 2, Pages: 53-56(2019)
作者机构:
1. 河钢集团邯钢公司技术中心汽车家电板研发中心,邯郸,056015
2. 河钢集团钢研总院,石家庄,050023
3. 北京科技大学工程技术研究院,北京,100083
作者简介:
基金信息:
DOI:
CLC:
Received:11 October 2018,
Online First:19 May 2022,
Published:19 May 2019
稿件说明:
移动端阅览
李俊生, 薛仁杰, 马娥, et al. Analysis on Strip Fracture of High Strength IF Steel Containing Phosphorus During Straightening in Pickling & Rolling and Process Improvement[J]. Special Steel, 2019, 40(2): 53-56.
DOI:
李俊生, 薛仁杰, 马娥, et al. Analysis on Strip Fracture of High Strength IF Steel Containing Phosphorus During Straightening in Pickling & Rolling and Process Improvement[J]. Special Steel, 2019, 40(2): 53-56.DOI:
Analysis on Strip Fracture of High Strength IF Steel Containing Phosphorus During Straightening in Pickling & Rolling and Process Improvement
scanning electron microscopy and auger electron spectroscopy were used to analyze the reasons of the strip fracture of high strength IF steel HC250IF containing phosphorus during straightening in pickling
&
rolling process. It is confinned that the content of B is too low and the segregation of P at grain boundary could not be inhibited
and the FeTiP or Fe3P compound formed at the grain boundary resulting in brittleness is the basic cause of strip fracture. By optimized process for adding boron
increasing the content of B from 0.0002% 〜0.0007% to 0.0008% ~ 0.0012%
controlling strictly the content N≤ 30 x 10
-6
and vacuum cycle for 8 min after adding the boron iron in RH process
it is to ensure the uniformity of the composition
the strip fracture of high strength IF steel containing phosphorus during straightening in pickling