An Experimental Method to Fast Determine Fatigue Limit of 0.45C Steel by Infrared Thermal Sensor Technology
|更新时间:2026-01-21
|
An Experimental Method to Fast Determine Fatigue Limit of 0.45C Steel by Infrared Thermal Sensor Technology
Special SteelVol. 29, Issue 4, Pages: 66-68(2008)
作者机构:
1. 江苏省特种设备安全监督检验研究院常州分院,常州,213002
2. 太原科技大学应用科学学院,太原,030024
作者简介:
基金信息:
DOI:
CLC:
Received:29 January 2008,
Online First:23 December 2022,
Published:23 December 2008
稿件说明:
移动端阅览
李飞, 马赞, 刘浩. An Experimental Method to Fast Determine Fatigue Limit of 0.45C Steel by Infrared Thermal Sensor Technology[J]. Special Steel, 2008, 29(4): 66-68.
DOI:
李飞, 马赞, 刘浩. An Experimental Method to Fast Determine Fatigue Limit of 0.45C Steel by Infrared Thermal Sensor Technology[J]. Special Steel, 2008, 29(4): 66-68.DOI:
An Experimental Method to Fast Determine Fatigue Limit of 0.45C Steel by Infrared Thermal Sensor Technology
The dissipation of energy-dissipation of heat during fatigue process of materials has been analyzed
and the surface temperature change of 0. 45C steel with necking part in fatigue test process by using high frequency fatigue test machine was studied by infrared thermal sensor to fast determine fatigue limit of 0. 45C steel. Results showed that the fatigue limit of normalized 0. 45C steel determined by infrared thermal sensor was 219 MPa
it was showing no difference with the fatigue limit of steel obtained by theoretical calculation. This method has the merits such as non-contact